24 years Professional Color Pigment Manufacturer
TEL: +8618520230133 Email: judy@md939.com
MR-939ATitaniumDioxide-SGS

Certifications

Guang Zhou Mei Dan Tioxide Co.,Ltd – SGS

NO.705, SECTION 3, BUILDING NO.1, PANSHAN INNOVATION SERVICE CENTER, PANYU ENERGY CONSERVATION SCIENCE AND TECHNOLOGY PARK, THE NORTHERN SECTION OF PANYU AVENUE, DONGHUAN STREET, PANYU DISTRICT, GUANGZHOU CHINA

The following sample(s) was/were submitted and identified on behalf of the clients as : TITANIUM DI0XIDE SGS Job No. : CP20-008479 – GZ

Model No. : MR939A

Client Ref. Info. : MR939A+;MR938;MR919;MR929;MR928

Main Substance : TiO₂

Date of Sample Received : 16 Mar 2020

Testing Period : 16 Mar 2020 – 20 Mar 2020

Test Requested : Selected test(s) as requested by client.

Test Method : Test Results :

Please refer to next page(s). Please refer to next page(s).

Conclusion : Based on the performed tests on submitted sample(s), the results of Lead,

Mercury, Cadmium, Hexavalent chromium, Polybrominated biphenyls (PBBs), Polybrominated diphenyl ethers (PBDEs) and Phthalates such as

Bis(2-ethylhexyl) phthalate (DEHP) , Butyl benzyl phthalate (BBP), Dibutyl phthalate (DBP) , and Diisobutyl phthalate (DIBP) comply with the limits as set by RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU.

Signed for and on behalf of

SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch

Violet,Shi Approved Signatory

Test Results :

Test Part Description :

Specimen No.. SGS Sample ID. Description. SN1 CAN20-029545.001 White powder

 

Remarks :

(1) 1 mg/kg = 0.0001%

  • MDL = Method DetectionLimit
  • ND = Not Detected ( < MDL)
  • “-” = NotRegulated

 

RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU .

 

Test Method : With reference to IEC 62321-4:2013+A1:2017, IEC 62321-5:2013, IEC 62321-7-2:2017 , IEC 62321-6:2015 and IEC 62321-8:2017, analyzed by ICP-OES , UV-Vis and GC-MS .

 

Test Item(s)

Limit

Unit

MDL

001

Cadmium (Cd)

100

mg/kg

2

ND

Lead (Pb)

1,000

mg/kg

2

ND

Mercury (Hg)

1,000

mg/kg

2

ND

Hexavalent Chromium (CrVI)

1,000

mg/kg

8

ND

Sum of PBBs

1,000

mg/kg

ND

Monobromobiphenyl

mg/kg

5

ND

Dibromobiphenyl

mg/kg

5

ND

Tribromobiphenyl

mg/kg

5

ND

Tetrabromobiphenyl

mg/kg

5

ND

Pentabromobiphenyl

mg/kg

5

ND

Hexabromobiphenyl

mg/kg

5

ND

Heptabromobiphenyl

mg/kg

5

ND

Octabromobiphenyl

mg/kg

5

ND

Nonabromobiphenyl

mg/kg

5

ND

Decabromobiphenyl

mg/kg

5

ND

Sum of PBDEs

1,000

mg/kg

ND

Monobromodiphenyl ether

mg/kg

5

ND

Dibromodiphenyl ether

mg/kg

5

ND

Tribromodiphenyl ether

mg/kg

5

ND

Tetrabromodiphenyl ether

mg/kg

5

ND

Pentabromodiphenyl ether

mg/kg

5

ND

 

 

Test Item(s)

Limit

Unit

MDL

001

Hexabromodiphenyl ether

mg/kg

5

ND

Heptabromodiphenyl ether

mg/kg

5

ND

Octabromodiphenyl ether

mg/kg

5

ND

Nonabromodiphenyl ether

mg/kg

5

ND

Decabromodiphenyl ether

mg/kg

5

ND

Dibutyl phthalate (DBP)

1,000

mg/kg

50

ND

Butyl benzyl phthalate (BBP)

1,000

mg/kg

50

ND

Bis (2-ethylhexyl) phthalate (DEHP)

1,000

mg/kg

50

ND

Diisobutyl Phthalates (DIBP)

1,000

mg/kg

50

ND

Notes :

    
  • Themaximum permissible limit is quoted from RoHS Directive (EU) 2015/863.IEC 62321 series is equivalent to EN 62321 series
  • Therestriction of DEHP, BBP, DBP and DIBP shall apply to medical devices, including in vitro medical devices, and monitoring and control instruments, including industrial monitoring and control instruments, from 22 July 
  • Therestriction of DEHP, BBP, DBP and DIBP shall not apply to toys which are already subject to the restriction of DEHP, BBP, DBP and DIBP through entry 51 of Annex XVII to Regulation (EC) No 1907/2006.

 

ATTACHMENTS

Pb/Cd/Hg/Cr6+/PBBs/PBDEs Testing Flow Chart

 

1) These samples were dissolved totally by pre -conditioning method according to below flow chart. (Cr6+ and PBBs/PBDEs test method excluded ).

Sample photo:

SGS authenticate the photo on original report only

*** End of Report **

    Contact MeiDan & Boom Your Business

    +8618520230133

    judy.md939

    +8618520230133

    2430032458

    Leave a message

      Contact MeiDan & Boom Your Business